Knowledge application
I. Chinese û International Standardî ji materyalên pakêta VCI
Mal |
Navnetewî |
Products Standard me |
VCI Paper |
JIS1535-1991 MIL-Artukluyê-3420H-2008 TL 8135 |
QB1319-2010 JIS Z 1535-1991 TL 8135 |
VCI Film Plastic |
MIL-Artukluyê-22019E-2010 TL8135 |
GB / T19532-2004 MIL-Artukluyê-22019E-2010 TL 8135 |
II. Bikaranîna materyalên VCI
The amount of VCI paper or VCI plastic film is equal to the surface area of the enclosing item in general. When applying VCI powder, the amount of VCI powder shall not be less than 35g/m3.
III. Application methods of VCI packaging materials
There are three application methods of VCI packaging materials.
1. The inner packaging materials: The parts are wrapped with VCI paper or VCI plastic film without any other material between the part and VCI materials.
2. The VCI powder can be used by hanging bag or spraying powder so that VCI can spread to surface of metal.
3. Separation di navbera tebeqeyên ji materyalên VCI: Di board tecrîda carton box bikaranîna VCI maddî pakêta, ji bilî di nav qutîkê de carton ketibûn, bi amûrên pakêta VCI de, di her layer ya plakaya, biçûkxistin, li ser rûyê jêrîn, her weha ji bo çermê materyalên pakêta VCI pêwîst
IV. Çi faktorên nizane materyalên VCI bikaranîna bandor li ser girêdayî?
1. The corrosion inhibition ability of VCI material itself, namely the volatilization rate of volatile corrosion inhibitor.
2. The degree of Protection required for a part, should be governed by its material, structure, precision .
3. The part should be sealed by VCI materials, the better sealing condition and the longer rustproof period.
V. What shall be paid attention to when applying VCI materials?
1. Select corresponding VCI materials according to component of part.
2. Parts containing plastic, painted, or rubber should not be packaged with VCI materials until passed the compatibility test.
3. Metal parts shall be cleaned and dried before applying VCI materials.
VI. Storage condition of VCI materials
1. VCI materials shall be well sealed and stored in a cool dry area.
2. The packaged VCI materials shall not be opened until ready for use.
3. In continuous preservation operation, the period of VCI materials exposed to open air shall be less than 8 hours.
VII. To protect Metal from corrosion is a systems engineering
During production, process interval, shipment of metal part, it is very necessary to set up management and technical requirement about metal corrosion. If one link in the production chain occurs corrosion, the damage will not be saving. The company will lose much. So the management of metal corrosion is a systems engineering. We shall prevent metal part from corrosion since the total life and every process of metal part.
VIII. Technological process of rustproof packaging
cleaning, drying, rust protection, packaging